PN ?????? Rev A
PN 2006313 Rev A
1
1
DirectCommand
TM
Strip Till / Air Cart
Quick Reference Guide
AL: 2006315 - ENG Rev B
Valve Response 1
fast speed of valve, decrease to slow response time
default = 40%
Valve Response 2
slow speed of valve, decrease to slow response time
default = 8%
Response Threshold
point where system switches between using
Response 1 and Response 2, increase to slow
response time, default = 15
Allowable Error
error allowed before making rate control adjustments
Shaft Speed Calibration
pulses/revolution of metering shaft
Max Metering Speed
maximum allowable RPM of metering system
Servo Valve
There is a tab for every channel of control with Control Valve Congurations and related settings.
Create Conguration
Enter Settings
Start of Conguration Wizard
Press to Highlight Conguration
4930rx
Application
Conguration Product
Application
Controller
Settings
Channel 1 Channel 2 Channel 3
Auxiliary
Control Valve Conguration
Channel 2 Channel 3 Auxiliary
Channel 1
Servo
Valve
Response 1
Valve
Response 2
Response
Threshold
Strip Till Control
Allowable
Error
Max Metering
Speed
Shaft Speed
Calibration
180 pls/rev
100 rpm
2 %
8 %
40 %
15
Vista de página 0
1 2 3 4 5 6 7

Resumo do Conteúdo

Página 1 - Strip Till / Air Cart

PN ?????? Rev APN 2006313 Rev A11DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BValve Response 1fast speed of valve,

Página 2

PN ?????? Rev APN 2006313 Rev A22DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BPWM Frequencyfrequency valve is pulse

Página 3

PN ?????? Rev APN 2006313 Rev A33DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BActuator Response 1fast speed of actu

Página 4

PN ?????? Rev APN 2006313 Rev A44DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BActual Rateactual rate of product bei

Página 5

PN ?????? Rev APN 2006313 Rev A55DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BBin Fullpress to ll containerBin Par

Página 6

PN ?????? Rev APN 2006313 Rev A66DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BBin Fullpress to ll containerBin Par

Página 7 - Quick Reference Guide

PN ?????? Rev APN 2006313 Rev A77DirectCommandTMStrip Till / Air CartQuick Reference GuideAL: 2006315 - ENG Rev BProduct Densityvalue (lb/ft3), is sto

Comentários a estes Manuais

Sem comentários